Your R&D Consultants
현재 위치 HOME
High Max Power Density for Pulsed Lasers
페이스북 공유하기 트위터 공유하기 아웃룩 공유하기
  • High Max Power Density for Pulsed Lasers

    High Max Power Density for Pulsed Lasers

  • High Max Power Density for Pulsed Lasers

    High Max Power Density for Pulsed Lasers

  • High Max Power Density for Pulsed Lasers
  • High Max Power Density for Pulsed Lasers

제조사(브랜드) THORLABS
판매사/수입사 4science
납기일 2~4주
담당자 정보 031-8018-7281
제품 사양서 인쇄
Cat. No. 모델명 제품명 사양 판매단위 판매가 수량
21-02978-01 S370C Thermal Power Sensor Head, Volume Absorber 0.4 - 5.2 µm, 10 W, Ø25 mm 1ea/pk 견적가
- +
21-02978-02 S470C Thermal Power Sensor Head, Volume Absorber 0.25 - 10.6 µm, 0.1mW - 5W, Ø15 mm 1ea/pk 견적가
- +
선택한 모델 총 0개

※ 최소 주문 가능 금액 : 3만원

부가세 포함 / 0 원
High Max Power Density for Pulsed Lasers

  • Designed for Optical Power Measurements of Nd:YAG Lasers
  • Ideal for Applications with High Peak Pulse Powers
  • S370C: Ø25 mm Aperture for Large-Spot-Size Beams
S470C: High-Sensitivity for High-Peak-Power Pulses with Low Average Power

The S370C and S470C Thermal Sensors are designed to measure short and highly energetic laser pulses. All of these units are post-mountable for free-space applications and feature NIST-traceable data stored in the sensor connector.

These thermal power sensors are unique in that they have thermal volume absorbers, where our other thermal power sensors have thermal surface absorbers. The volume absorber consists of a Schott glass filter. Incident pulses are absorbed and the heat is distributed throughout the volume. In this way, pulses that would have damaged the absorption coating of a thermal surface absorber are safely measured by these thermal volume absorbers. 

The S370C features a large Ø25 mm aperture ideal for large-spot-size beams, and it is compatible with average powers from 10 mW to 10 W (CW).

In comparison, the S470C is faster, as the glass absorber volume is reduced and other design parameters have been optimized for speed. This results in a different optical power range, with the ability to measure powers down to 100 µW. The Ø15 mm aperture is of the S470C is smaller, and it has a lower max average power of 5 W. Its 10 µW resolution is better than the 250 µW resolution of the S370C.

Thorlabs offers a recalibration service for these sensors, which can be ordered below (see Item # CAL-S200).



This absorption curve is shown over a broader wavelength range than the sensors' operating ranges.
See the table for the operating wavelength range of each sensor.



Item #a S370C S470C
Sensor Image
Wavelength Range 400 nm - 5.2 µm 250 nm - 10.6 µm
Optical Power Range 10 mW - 10 W (15 Wb) 100 µW - 5 W (Pulsed and CW)
Input Aperture Size Ø25 mm Ø15 mm
Active Detector Area Ø25 mm Ø16 mm
Max Optical Power Density 35 W/cm² (Avg.); 100 GW/cm² (Peak)
Detector Type Thermal Volume Absorber (Thermopile)
Linearity ±1% ±0.5%
Resolutionc 250 µW 10 µW
Measurement Uncertaintyd ±3% @ 1064 nm
±5% @ 400 nm - 1064 nm
±3% @ 1064 nm
±5% @ 250 nm - 10.6 µm
Response Timee 45 s 
(3 s from 0 to 91%)
6.5 s
(<2 s from 0 to 90%)
Cooling Convection (Passive)
Housing Dimesions
(Without Adapter, if Applicable)
75 mm x 75 mm x 51.2mm
(2.95" x 2.95" x 2.02")
45.0 mm x 45.0 mm x 18.0 mm
(1.77" x 1.77" x 0.71")
Temperature Sensor
(In Sensor Head)
N/A N/A
Cable Length 1.5 m
Post Mounting M6 Threaded Taps, Includes
Ø1/2" Post, 75 mm Long
Universal 8-32 / M4 Tap
(Post Not Included)
30 mm Cage Mounting Four 4-40 Tapped Holes -
Aperture Threads - External SM1
Accessories Externally SM1-Threaded Adapter -
Compatible Consoles PM400, PM200, PM100A, PM100USB, and PM320E

  1. For complete specifications, please see the Specs tab.
  2. Two Minute Maximum Exposure Time.
  3. Measurement taken with the PM100D console for the S370C and with the PM200 for the S470C. In all cases, the acceleration circuit was switched off. Resolution performance will be similar with our other power meter consoles..
  4. Defined as the measurement uncertainty during calibration at the specified wavelengths for a beam diameter > 1 mm. The ±3% specification was determined by laser calibration, and the ±5% specification was determined through spectral calibration, in which values were interpolated using the laser calibration data and the absorption curve for the absorber. Calibration can be performed at 10.6 µm upon request.
  5. Typical natural response time (0 - 95%). Our power consoles can provide estimated measurements of optical power on an accelerated time scale (typically Operation tab for additional information

포사이언스에서는 다음과 같은 기간 및 내용으로 상품 및 용역에 대하여 교환, 반품, 환불을 보장하고 있으며, 상품의 반환에 의한 추가비용을 고객에게 부담시키지 않습니다.
(단, 고객 변심 또는 주문 번복으로 인한 경우의 반환비용은 고객님이 부담하셔야 합니다.)


1. 단순변심일경우 : 물품수령 후 7일이내 반품가능(반품배송비 구매자가 부담)
2. 표시, 광고 내용과 상이하거나 물품 하자인 경우 : 물품수령 후 3개월이내, 또는 그 사실을 안날 또는 알수 있었던 날로부터 30일이내 반품가능 (반품배송비 판매자가 부담)

단, 아래의 내용인 경우에는 교환/반품/환불이 불가능하오니 참조하시기 바랍니다.

1. 반품요청기간이 지난 경우
2. 고객님의 책임있는 사유로 상품등이 멸실 또는 훼손된 경우(단 상품의 내용을 확인하기 위하여 포장 등을 훼손한 경우는 제외)
3. 주문 당시 해외 발주 상품의 경우
4. 고객의 요청으로 주문제작이 이루어진 경우
5. 포장을 개봉하였거나 포장이 훼손되어 상품의 가치가 현저하게 감소한 경우
6. 고객님의 사용 또는 일부 소비에 의하여 상품의 가치가 현저히 감소한 경우
7. 재판매가 곤란한 정도로 상품등의 가치가 현저히 감소한 경우
8. 복제가 가능한 상품 등의 포장을 훼손한 경우

주문 취소 및 반품으로 환불을 요청하실 경우에는 E-mail(sales@4science.net) 상담서비스나 고객만족센터(1644-4214)를 통해 요청하시면 친절하게 처리해 드리겠습니다.
주문 취소 후 반품 가능 여부를 확인한 다음 3일 이내에 결제 금액을 환불해 드리겠습니다.
본 상품을 구매하신 고객님께서 작성하신 상품평입니다.
등록된 제품 이외의 사양이 필요하시다면 상품문의를 남겨주세요.